You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 133 No. 1, January 2007 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on ISI (2)
 •Contact me when this article is cited
 Related Content
 •Related article
 •Similar articles in this journal
 Topic Collections
 •Airway Obstruction
 •Endoscopy of Upper Aerodigestive Tract
 •Pediatric Otolaryngology
 •Surgery
 •Alert me on articles by topic

Robotic Surgery in the Pediatric Airway

Application and Safety

Reza Rahbar, DMD, MD; Lynne R. Ferrari, MD; Joseph G. Borer, MD; Craig A. Peters, MD

Arch Otolaryngol Head Neck Surg. 2007;133(1):46-50.

Objective  To assess the application and safety of transoral robotic surgery in the pediatric airway.

Design  An institutional review board–approved study. Experimental laryngeal surgery was performed on 4 pediatric cadaver larynxes as controls. Application of robotic equipment for laryngeal surgery was attempted on 5 patients.

Setting  Tertiary care pediatric medical center.

Patients  Five patients with laryngeal cleft and 4 pediatric cadaver larynxes.

Interventions  (1) The da Vinci Surgical Robot (Intuitive Surgical Inc, Sunnyvale, Calif) was used on 4 cadaver larynxes and assessed for the dexterity, precision, and depth perception that it allowed the surgeon during laryngeal surgery. Procedures were documented with still and video photography. (2) The da Vinci Surgical Robot was used through a transoral approach to attempt repair of a laryngeal cleft in 5 pediatric patients who were under spontaneously breathing general anesthesia.

Results  (1) Use of the surgical robot on cadaver larynxes provided great dexterity and precision, delicate tissue handling, good 3-dimensional depth perception, and relatively easy endolaryngeal suturing. (2) The surgical robot could not be used for repair of laryngeal cleft on 3 patients owing to limited transoral access. However, 1 patient with a type 1 laryngeal cleft and 1 patient with a type 2 laryngeal cleft underwent transoral robotic repair with great success.

Conclusions  Surgical robots provide the ability to manipulate instruments at their distal end with great precision, increased freedom of movement, and excellent 3-dimensional depth perception. The size of the equipment can be a limiting factor with regard to the application and success of the transoral approach to airway surgery. We believe that further advances in device technology and a new generation of robotic equipment will facilitate the incorporation of surgical robotics in the advancement of minimally invasive endoscopic airway surgery.


Author Affiliations: Departments of Otolaryngology and Communication Disorders (Dr Rahbar), Anesthesia (Dr Ferrari), and Urology (Dr Borer), Children's Hospital Boston, Harvard Medical School, and Department of Otology and Laryngology, Harvard Medical School (Dr Rahbar), Boston, Mass; and Department of Urology, University of Virginia, Charlottesville (Dr Peters).


RELATED ARTICLE

Robotic Surgery in the Pediatric Airway—Invited Commentary
Marvin P. Fried and Sanjay R. Parikh
Arch Otolaryngol Head Neck Surg. 2007;133(1):50.