You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 126 No. 8, August 2000 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (12)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Airway Obstruction
 •Cancer Reconstruction of Head & Neck
 •Alert me on articles by topic

Use of Internal Bioabsorbable PLGA "Finger-Type" Stents in a Rabbit Tracheal Reconstruction Model

Thomas C. Robey, MD; Tero Välimaa, MSc; Hedwig S. Murphy, MD, PhD; Pertti Tôrmâlâ, PhD; David J. Mooney, PhD; Robert A. Weatherly, MD

Arch Otolaryngol Head Neck Surg. 2000;126:985-991.

Objectives  To design and develop a biodegradable tracheal stent that can be used internally to stabilize and support surgically reconstructed airways.

Design  In vitro mechanical and degradative properties of 80:20 poly(D,L-lactide-co-glycolide) (PLGA) "finger-like" stents were determined. The stents were then tested in vivo in rabbits that underwent anterior patch tracheoplasties with fascia lata grafts. Comparisons were made between a control group and an internal stent group for stridor development, overall group mortality, reconstructed airway lumen size, and histological findings.

Subjects  Twenty-five New Zealand white rabbits.

Results  The average dry modulus for the internal stents was 6800 kPa. All of the internal stents cracked by 4 weeks in buffer solution. Significant mass loss was not noted in vitro until after 5 weeks in buffer solution. By 14 weeks, the stents were nearly 100% degraded. The attrition rate for the control group was 23% compared with 17% for the experimental group. The stridor rate for the control group was also higher at 38% compared with 17% for the stented group. The stented rabbits had a significantly smaller average stenosis (23%) across the entire reconstruction site than the control group (34%) (P<.05).

Conclusion  Biodegradable PLGA stents degrade in a predictable fashion and have a statistically significant effect in augmenting anterior patch tracheoplasties with fascia lata grafts in rabbits.


From the Departments of Otolaryngology–Head and Neck Surgery (Drs Robey and Weatherly), Biologic and Material Sciences and Chemical Engineering (Dr Mooney), and Pathology (Dr Murphy), University of Michigan, Ann Arbor; the Department of Pathology and Laboratory Medicine, Veterans Affairs Medical Center, Ann Arbor (Dr Murphy); and the Institute of Biomaterials, Tampere University of Technology, Tampere, Finland (Mr Välimaa and Dr Tôrmâlâ).



THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Tracheal Reconstruction Using Tissue-Engineered Cartilage
Grimmer et al.
Arch Otolaryngol Head Neck Surg 2004;130:1191-1196.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2000 American Medical Association. All Rights Reserved.