You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 121 No. 1, January 1995 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Articles
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Rigid Fixation of Vascularized Bone Grafts in Mandibular Reconstruction

Neal D. Futran, MD, DMD; Mark L. Urken, MD; Daniel Buchbinder, DMD; Juan F. Moscoso, MD; Hugh F. Biller, MD

Arch Otolaryngol Head Neck Surg. 1995;121(1):70-76.


Abstract

Objective
To evaluate the nature of complications and complication rates with the use of three different reconstruction plates for the rigid fixation of vascularized bone grafts in oromandibular reconstruction.

Design
We conducted a case series of 95 patients over a 6-year period, with a minimum follow-up of 6 months and a maximum follow-up of 66 months.

Setting
Academic tertiary referral medical center.

Patients
Forty-eight patients had vascularized bone grafts fixated to native mandible with AO stainless steel reconstruction plates; 25 patients, with AO titanium plates; and 22 patients, with titanium hollow screw reconstruction plates (THORPs). Types of vascularized flaps, mandibular defects to be reconstructed, and use of radiation therapy were similar among the three groups.

Intervention
The surgical approach involved oromandibular reconstruction with a vascularized bone graft rigidly fixated with a reconstruction plate.

Outcome Measures
Clinically and radiographically noted complications and resultant treatment.

Results
In the grafts fixated with AO stainless steel reconstruction plates, three plate fractures, seven instances of loose screws, eight plate exposures, and two cases of nonunion occurred. No cases of plate fracture or nonunion occurred in the titanium or THORP groups. One titanium plate and two THORPs were exposed during the study period. One instance of loose screws occurred in the titanium group; none in the THORP group. Seventy-four percent of those complications occurred within 12.4 months (the mean follow-up time of the THORP group). The incidence of complications in the stainless steel group was significantly greater than that in the titanium or THORP groups. No statistically significant increase in the rate of complications was noted when radiation therapy was used as a component of treatment.

Conclusions
To our knowledge, this is the first study to compare three different reconstruction plates for fixation in vascularized bone reconstruction of the mandible. AO THORPs are now used almost exclusively to rigidly fixate vascularized bone grafts because of their advanced design and their potential for osseointegration and because fewer screws are necessary to attain adequate fixation than with conventional AO reconstruction plates.

(Arch Otolaryngol Head Neck Surg. 1995;121:70-76)



Author Affiliations

From the Division of Otolaryngology, University of South Florida, Tampa (Dr Futran), and the Departments of Otolaryngology (Drs Urken, Moscoso, and Biller) and Oral and Maxillofacial Surgery (Dr Buchbinder), Mount Sinai Medical Center, New York, NY.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Evaluation of Hardware-Related Complications in Vascularized Bone Grafts With Locking Mandibular Reconstruction Plate Fixation
Knott et al.
Arch Otolaryngol Head Neck Surg 2007;133:1302-1306.
ABSTRACT | FULL TEXT  

Comparison of Radial Forearm With Fibula and Scapula Osteocutaneous Free Flaps for Oromandibular Reconstruction
Militsakh et al.
Arch Otolaryngol Head Neck Surg 2005;131:571-575.
ABSTRACT | FULL TEXT  

Closure of Mucosal Defects Over Exposed Mandibular Plates Using Fibrin Glue
Gaboriau et al.
Arch Facial Plast Surg 1999;1:191-194.
ABSTRACT | FULL TEXT  

Oromandibular Reconstruction With the Fibular Free Flap: Analysis of 50 Consecutive Flaps
Shpitzer et al.
Arch Otolaryngol Head Neck Surg 1997;123:939-944.
ABSTRACT  

Factors Involved in Long- and Short-term Mandibular Plate Exposure
Nicholson et al.
Arch Otolaryngol Head Neck Surg 1997;123:217-222.
ABSTRACT  

Lateral Mandibular Reconstruction Using Soft-Tissue Free Flaps and Plates
Blackwell et al.
Arch Otolaryngol Head Neck Surg 1996;122:672-678.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1995 American Medical Association. All Rights Reserved.