You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 118 No. 3, March 1992 TABLE OF CONTENTS
  Archives
  •  Online Features
  ORIGINAL ARTICLES
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

The Effects of Nasal Dilation on Snoring and Obstructive Sleep Apnea

Ulf Höijer, MD; Hasse Ejnell, MD, PhD; Jan Hedner, MD, PhD; Björn Petruson, MD, PhD; Lennart B. Eng

Arch Otolaryngol Head Neck Surg. 1992;118(3):281-284.


Abstract

• The effects of nasal valve dilation on snoring and obstructed breathing were studied in 11 patients with habitual snoring and/or obstructive sleep apnea. The anterior part of the nose, the valve region, was dilated by means of a plastic device. Ten patients underwent polysomnographic investigation including pulse oximetry and measurement of snoring noise with and without the nasal dilator in a randomized manner. Snoring, nocturnal arousals, and daytime hypersomnolence were rated by the patient and partner on a questionnaire before and after a 10-day treatment period with the dilator. The nasal airflow, as assessed by rhinomanometry when awake in the sitting position, increased by 18% (range, 5.5% to 45%) when the nasal dilator was used. The frequency and severity of obstructed breathing decreased significantly with the nasal dilator. The apnea index with and without the nasal dilator was 6.4 (range, 1.3 to 15) and 18 (range, 1.8 to 60), respectively. The mean decrease of the apnea index was 47%. The overnight minimum arterial oxygen saturation ( with and without the nasal dilator was 84% (range, 76% to 88%) and 78% (range, 68% to 89%), respectively. There was a substantial decrease in snoring noise (number of epochs with Leq values, equal energy level, above 55 or 60 dB) with the dilator in all patients who presented with snoring noise above these levels during the control night. No subjective effects on arousal frequency or daytime hypersomnolence were reported. Four of 11 patients were positive to continue using the nasal dilator.

(Arch Otolaryngol Head Neck Surg. 1992;118:281-284)



Author Affiliations

From the Departments of Otorhinolaryngology (Drs Höijer, Ejnell, and Petruson), Clinical Pharmacology (Dr Hedner), and Occupational Audiology (Mr Eng), Sahlgrenska Hospital, University of Göteborg (Sweden); and the Department of Otorhinolaryngology V Frölunda (Sweden) Hospital (Dr Höijer).


Footnotes

Accepted for publication September 18, 1991.

Reprint requests to the Department of Otorhinolaryngology V Frölunda Hospital, S-421 22, Frölunda, Sweden (Dr Höijer).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Sleep-Disordered Breathing, Snoring, Upper Airway Resistance Syndrome, and Complex Sleep Apnea: Medical, Nonpulmonary Airway Pressure Therapy for Obstructive Sleep Apnea
Gay and Brown
ACCP Sleep Med Brd Rev 2009;4:259-270.
FULL TEXT  

The role of the nose in the pathogenesis of obstructive sleep apnoea and snoring
Kohler et al.
Eur Respir J 2007;30:1208-1215.
ABSTRACT | FULL TEXT  

Snoring Is Not Relieved by Nasal Surgery Despite Improvement in Nasal Resistance
Virkkula et al.
Chest 2006;129:81-87.
ABSTRACT | FULL TEXT  

Effect of treating severe nasal obstruction on the severity of obstructive sleep apnoea
McLean et al.
Eur Respir J 2005;25:521-527.
ABSTRACT | FULL TEXT  

The Effect on Snoring of Structural Nasal Valve Dilatation With a Butterfly Graft
Akcam et al.
Arch Otolaryngol Head Neck Surg 2004;130:1313-1318.
ABSTRACT | FULL TEXT  

Use of external nasal dilator strips in motor neurone disease with upper airways obstruction
Sloan
Palliat Med 1999;13:443-443.
 

Better Quality of Life When Nasal Breathing of Snoring Men Is Improved at Night
Loth et al.
Arch Otolaryngol Head Neck Surg 1999;125:64-67.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1992 American Medical Association. All Rights Reserved.