You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 117 No. 10, October 1991 TABLE OF CONTENTS
  Archives
  •  Online Features
  ORIGINAL ARTICLES
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Objective Low-Frequency Audiometry by Distortion-Product Acoustic Emissions

Pierre Bonfils, MD, PhD; Paul Avan, MD; Alain Londero, MD; Jacques Trotoux, MD; Philippe Narcy, MD

Arch Otolaryngol Head Neck Surg. 1991;117(10):1167-1171.


Abstract

• The aim of this study was to measure distortion-product otoacoustic emissions (DPOEs) in a clinical setting. First, DPOE input-output functions were automatically realized to determine the ratio of the pure tones (primaries) f2 and f1 that would elicit the most significant DPOE input-output function. The DPOE input-output functions presented two separate portions for the f2/f1 ratio, ranging from 1.18 to 1.26: (1) below 60-dB sound pressure level (SPL), a saturating portion with a DPOE detection threshold at 36-dB SPL; and (2) above 66-dB SPL, a linear portion. For other f2/f1 ratios, DPOE input-output functions had a more linear behavior. The DPOEs generated by primary intensities below 60-dB SPL, which show saturating behavior, probably have their origin in the properties of outer hair cells. This indicates that DPOE measurements in a clinical setting must be realized with precise stimulus values: (1) f2/f1 ratio near 1.22, and (2) primary intensities below 60-dB SPL. Second, DPOE input-output functions were realized for DPOEs varying from 707.5 to 342 Hz. No more saturating plateau could be observed with DPOEs below 512.5 Hz, suggesting that active mechanisms are absent below 725 Hz within the human cochlea. These data permit us to establish the bases of an objective low-frequency audiometric test.

(Arch Otolaryngol Head Neck Surg. 1991;117:1167-1171)



Author Affiliations

From the Department of Otorhinolaryngology, Hospital Robert Debré, Faculty Xavier Bichat (Drs Bonfils and Narcy), and the Department of Biophysics, Hospital Lariboisiére, Faculty Lariboisiére (Dr Avan), University of Paris VII, and the Department of Otorhinolaryngology, Hospital Boucicaut, Faculty Necker-Enfants-Malades, University of Paris V (Drs Bonfils, Londero, and Trotoux), Paris, France.


Footnotes

Accepted for publication February 6, 1991.

Reprint requests to Hôpital Boucicaut, 78 rue de la Convention, F-75015 Paris, France (Dr Bonfils).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Distortion-Product Otoacoustic Emissions: Values for Clinical Use
Bonfils and Avan
Arch Otolaryngol Head Neck Surg 1992;118:1069-1076.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP