You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 105 No. 6, June 1979 TABLE OF CONTENTS
  Archives
  •  Online Features
  ORIGINAL ARTICLES
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

A Protocol for the Air Caloric Test and a Comparison With a Standard Water Caloric Test

John R. Tole, ScD

Arch Otolaryngol. 1979;105(6):314-319.


Abstract

• This communication describes the development of a protocol for the air caloric stimulus for vestibular testing. The protocol is based on matching the peak responses of air and water caloric stimuli and minimizing subject discomfort. Air stimulus temperatures of 30 and 44 °C are used, and these appear to minimize subject complaints of pain with the test. Composite data are presented from 16 normal subjects who were tested with the protocol. A comparison is made with their responses to a standard water protocol. Test-retest data for both air and water protocols are also presented, and these data indicate similar day-to-day variation in the two methods. On the basis of the work presented, it is concluded that the air protocol produces responses equivalent to that of standard water calorics in a group of normal subjects. Neither test was found, in the present experiments, to be particularly sensitive.

(Arch Otolaryngol 105:314-319, 1979)



Author Affiliations

From the Man Vehicle Laboratory, Massachusetts Institute of Technology, Cambridge.


Footnotes

Accepted for publication Jan 12, 1978.

Reprint requests to Biomedical Engineering Center for Clinical Instrumentation, Room 20A-113, Massachusetts Institute of Technology, Cambridge, MA 02139 (Dr Tole).